Satel CA10 plus - LCD keypad Programming and Installation Manual
- 14 -
turned on after a key is pressed and then turned off after time set with use of option
“Long illumination” (40 or 150 seconds).
Status format
The function selects the panel's operation mode:
text mode ("descriptions"): system status is communicated by means of textual
messages,
zones according to CA10 plus mode: status of maximum of 12 zones is displayed
according to the list programmed with panel service functions FS12-FS15,
zones according to LCD mode: status of maximum of 16 selected zones is
displayed, indicating violations, alarms, tamper conditions, alarm log etc.
GOTO function
GOTO function performed on LCD keypad is easier then on LED one. LCD keypad
allows zone switching without returning to the base zone (the key
[
*
]
). This menu
selects partitions to which switching with GOTO is allowed.
Activation of the function needs programming service function of LCD keypad. In menu
Settings
¤
Function GOTO
we can specify the partitions to which we can go with
GOTO function.
After confirming the partitions selection LCD keypad will perform FS-124 service
function, which will set addresses of LCD keypads proper for the current configuration.
Notes:
If more than one LCD keypad is installed in the system, function GOTO settings
should be separately programmed in each keypad.
In the case of installation with an LCD keypad, expanders adapted to LCD
keypads should be used (software version 2, manufactured since February
1998). Older expander versions will also operate with LCD keypads, but will not
support multipartition systems.
Options
The functions enables setting some additional parameters, such as:
display exit delay time left,
exit delay sound signaling type,
beep on key pressed,
change back-lighting on key pressed,
how long to wait for pressing next key (40s / 150s),
is illumination of keypad and display to be permanent,
are functions assigned to arrow keys to be active.
{Status priority} parameter determines the way system status is displayed in the text
mode. If it is off all relevant messages are displayed one after another in a closed cycle.
If it is on only the highest priority message is displayed.