13. Brief description of operating the system from keypad
– 1. group (numbers: 1-32 / addresses 00-1F)
blinking – trouble or trouble memory / Grade 3:
trouble or trouble memory, bypassed zones or
alarm
– 2. group (numbers: 33-64 / addresses 20-3F)
– 3. group (numbers: 65-96)
– 4. group (numbers: 97-128)
– LED OFF; – LED ON (
ON – all partitions operated by the keypad are
armed
blinking – service mode started
blinking – some partition
s are armed
ON or blinking – alarm or alarm memory
[CODE] – arming / disarming / alarm clearing
Quick arming:
0 - full arming
1 - full arming + bypasses
2 - arming without interior
3 - arming without interior and without entry
delay
9 – end of exit delay countdown
8 – quick control of outputs
[HASŁO] – enter the user menu
User me
nu shortcuts:
1 Cha
nge own code
2 Users [Masters]
21 New user [New master]
22 Edit user [Edit master]
23 Remove user [Remove master]
4 Zone bypasses
41 Inhibit
42 Isolate
5 Events
51 Selected events
Shortcut keys (press for approx. 3 seconds):
52 All events
1 – check zone status
6 Set time
4 – che
ck partition status
7 Sy
stem state
5 – view alarm log
8 Outputs control
6 – view trouble log
9 Service mode
7 – view current trouble
s
0 Do
wnlo
ading
8 – CHIME signal O
N/OFF
01 Start DW
NL-RS
9 – toggle display betwe
en standby mode and partition
status mode
02 Finish DW
NL-RS
03 Start DWNL-MOD.
– trigger medical (aux) alarm
04 Start
DW
NL-TEL
– trigger fire alarm
07 ETHM-1 – Dl
oadX
– trigger panic alarm
08 ETHM-1 – G
uardX
Vista de página 47