confirmation, if the selected user is to be deleted. If not, press the [
*
] key, if yes, press
the [#] key. The numbers of users from 10 to 12 can be entered by pressing two keys,
first the key of tens [
*
], then the key of units (from 0 to 2).
In the LCD keypad, the user indicated by the cursor (flashing field) will be deleted. On
pressing and holding down the or key the name of the user indicated with the
cursor appears. The cursor can be positioned with .
The function is only available to the master user.
Example: deleting the third user’s access code (master code = 1234)
[1234] [
*
] - activating the „user function” mode by the master user,
[3] - calling the „delete code” function, the zone LEDs indicate the partition
users' numbers.
[3] - selecting the code to delete; the LED of the chosen code starts blinking
[#] - selected user code deletion; four short and one longer beeps signal the end
of the function.
Zone bypass [CODE][
*
][4]
This function makes it possible to bypass zones in order to partially arm the alarm
system or to bypass malfunctioning detectors. Only disarmed zones can be bypassed.
In the LED keypad, bypassing a zone consists in entering the number of the LED on
which the given zone is indicated. Only the zones belonging to the keypad served
partition can be bypassed. The zones 1-12 can only be bypassed when they are
indicated on the keypad LEDs. The installer decides about which zones should be
indicated. The zones 13-16 can be bypassed by entering the zone number even when
they are not indicated on the LEDs. When the bypass function is in use, the LED
keypad indicates the state of max. 12 zones. With the zones bypassed, the
corresponding LEDs are blinking. Enter the numbers of LEDs / zones from 10 to 16 by
pressing two keys, first the key of tens [
*
], then the key of units (from 0 to 6). Confirm
the choice by pressing [#]. The zones will remain bypassed until next disarming or until
they are unbypassed.
When the function is active, on entering a zone number, the panel will signal bypassing
the zone with two beeps, and enabling the zone with one beep. Two long beeps mean
that the zone belongs to another partition, or it is armed and its bypassing is not
possible.
In the LCD keypad key changes the status of the zone (bypassed - unbypassed)
indicated by the cursor. Pressing key displays the zone name. The cursor can be
positioned with keys. It is possible to choose a zone by giving its number with the
numeric keys of the panel (for example: [
*
][3] will enable bypassing of zone 13).
The function is available only to the master user and the user with authority level 1.
Example: bypassing zones 3, 5 and 12 (master access code = 1234)
[1234] [
*
] - activating the „user function” mode by the master user,
[4] - calling the „Zone bypass” function,
[3][5] - selecting zones numbers 3 and 5; the panel will confirm the entry of each
number by with two short beeps,
[
*
][2] - selecting zone number 12; the panel will confirm the entry with two short
beeps,
[#] - confirmation of the data and quitting of the function programming.